Home / Products / Marine Compressors

Marine screw & piston compressors

GRF-10C to GRF-350C screw packages (7.5–250 kW) and ZFC / VFC / WFC piston compressors for 3.0 MPa starting air — designed, built and surveyed to classification-society rules.

Water cooledGRF-100C water-cooled marine screw compressor with control cabinet

Water-Cooled Packages

Seawater/fresh-water cooled units for continuous marine duty; three-stage oil separation keeps carry-over below 3 ppm.

Air cooled · screwGRF-50C blue air-cooled enclosed marine screw compressor

Air-Cooled Screw · Enclosed

The blue enclosed canopy packages are air-cooled: sound-attenuated, controller-integrated, delivered as box or complete skid with class-certified pressure parts.

Open-frame air-cooled marine piston compressor with belt-driven fan

Marine Piston Compressors

Open-frame air-cooled piston sets ZFC / VFC / WFC for 3.0 MPa engine starting air — high pressure, intermittent duty, the highest reliability requirement on board.

Marine-grade build

  • Corrosion-protected components
  • Low vibration & noise
  • Auto control & protection

Clean air for N₂ plants

  • Three-stage oil separation
  • < 3 ppm oil carry-over
  • Stable feed pressure

Class certification

  • CCS / BV / RS / ABS approvals held
  • 10+ society rules covered
  • CE & ECM approved

Starting air

  • WFC-90 starting sets
  • With air receivers
  • Up to 30 bar duty
Technical data

GRF series — air-cooled & water-cooled

Capacities at 12.5 / 10 / 8 bar. Switch units between m³/min and CFM, or search a model.

Marine screw compressor data

ModelMotor (kW)12.5 bar (m³/min)10 bar (m³/min)8 bar (m³/min)Weight (kg)OutletL×W×H (mm)
Belt driven · air cooled · 7.5–45 kW
GRF-10C7.50.70.81.13203/4"1100×800×1000
GRF-15C111.01.21.63203/4"1100×800×1000
GRF-20C151.51.82.43503/4"1100×800×1000
GRF-25C18.51.72.02.85501"1280×1000×1150
GRF-30C222.63.13.46001"1280×1000×1150
GRF-40C303.23.85.07501"1280×1000×1150
GRF-50C374.85.66.48501 1/4"1500×1100×1350
GRF-60C455.36.27.69001 1/4"1500×1100×1350
Direct driven · air cooled · 55–110 kW
GRF-75C557.28.59.51700DN501750×1250×1520
GRF-100C758.510.012.41900DN501750×1250×1520
GRF-120C9011.113.015.02250DN652250×1330×1650
GRF-150C11013.215.519.32350DN652250×1330×1650
ModelMotor (kW)12.5 bar (m³/min)10 bar (m³/min)8 bar (m³/min)Weight (kg)OutletL×W×H (mm)
Belt driven · water cooled · 22–45 kW
GRF-30C222.53.13.4850DN401700×1100×1350
GRF-40C303.33.85.0900DN401700×1100×1350
GRF-50C374.55.66.4950DN401700×1100×1350
GRF-60C455.26.27.6980DN401700×1100×1350
Direct driven · water cooled · 55–250 kW
GRF-75C556.58.59.31250DN502200×1400×1410
GRF-100C758.99.512.41350DN502200×1400×1410
GRF-120C9010.813.015.01850DN652200×1400×1410
GRF-150C11014.015.019.32150DN652200×1400×1410
GRF-175C13217.519.522.52800DN802500×1550×1690
GRF-220C16021.224.526.73000DN802500×1550×1690
GRF-250C18521.226.730.03200DN802500×1550×1690
GRF-270C20026.729.032.53500DN1002800×2000×1831
GRF-300C22028.832.237.53800DN1002800×2000×1831
GRF-350C25031.637.540.04000DN1002800×2000×1831
  1. Capacities measured at standard conditions (suction 20 °C, 0.1 MPa abs., 0 % RH), tolerance ±5 %.
  2. Air-cooled units are limited to 110 kW (GRF-150C); 132 kW and above are water-cooled only.
  3. Standard discharge pressures are 12.5 / 10 / 8 bar; up to 15 bar on request, agreed in the order technical agreement.
  4. Air-cooled units recommended for ambient ≤ 45 °C with good ventilation. Weights and dimensions refer to the skid-mounted unit, excluding dryers and receivers; actual delivery prevails.
  5. Parameters are for reference; the company reserves the right to change them without notice.
Starting air · 3.0 MPa

Marine piston compressors — ZFC / VFC / WFC

A screw machine excels at continuous, medium-pressure, high-flow duty; a piston machine at high pressure, intermittent, low flow — exactly what engine starting air demands above 30 bar, with the highest reliability requirement on board. Three air-cooled series, seven ratings.

Piston compressor data · 3.0 MPa starting air · air cooled

ModelFlow capacityPressure (MPa)Motor (kW)CoolingSpeed (r/min)Weight (kg)L×W×H (mm)
ZFC series · single-cylinder arrangement
ZFC-33#14.5 m³/h3.04Air cooled15002431215×520×637
ZFC-33#22.0 m³/h3.05.5Air cooled15002651215×520×637
VFC series · two-cylinder arrangement
VFC-43#30.0 m³/h3.07.5Air cooled15003251215×520×637
VFC-43#44.0 m³/h3.011Air cooled15004501500×800×1100
WFC series · three-cylinder arrangement
WFC-901.0 m³/min (60 m³/h)3.015Air cooled14604501500×800×1100
WFC-901.6 m³/min (96 m³/h)3.018.5Air cooled14606001600×900×1100
WFC-902.0 m³/min (120 m³/h)3.022Air cooled14606501600×900×1100
  1. ZFC / VFC capacities are stated in m³/h; WFC-90 follows the manufacturer's piston table in m³/min with the m³/h equivalent in brackets. The screw range uses m³/min — bases differ and are not directly comparable.
  2. Z / V / W denote one- / two- / three-cylinder arrangements; motor power and capacity combinations are selected against bottle charging time.
  3. Dedicated solutions exist for blackout recovery, water-mist firefighting and breathing-air (SCBA / EEBD) charging.
  4. Parameters are for reference only; the company reserves the right to change them without notice.
Proven on board

Selected marine references

FSRU · RS

Wison F462, 45,000 m³ FSRU

GRF-300DSCW two-stage + GRF-300C, GRF-120C and WFC-90 on one vessel.

FPSO · BV

PETRONAS Sepat FPSO

220 kW utility/instrument air skids, 690 V, 30-year design life.

Scrubber · CCS/BV

MSC fleet retrofits

30 sets on 20+ container vessels with EN/CN documentation.

Full track record Request marine datasheet

Need a compressed-air solution for your vessel or plant?

Send us the duty point — flow, pressure, power supply and class society — and our engineers reply with a sized proposal.

Request a Quote