Home / Products / GRF industrial series

GRF MZD Membrane Nitrogen Packages

MZD membrane nitrogen packages, 200–1,500 m³/h at 25/35 bar, Ube membranes, V-type piston boosting, electric or diesel drive.

GRF MZD Membrane Nitrogen Packages
200–1,500 m³/h · 25/35 bar · electric/diesel

GRF MZD Membrane Nitrogen Packages

MZD membrane nitrogen packages, 200–1,500 m³/h at 25/35 bar, Ube membranes, V-type piston boosting, electric or diesel drive.

Overview

MZD combines membrane separation with V-type piston boosters, three or four stages to 25/35 bar. Membranes are Ube (Japan) modules, 3–20 per flow; electric drive with genset or diesel (TBD234/KTA19/NTA855) for oilfield, offshore and mobile nitrogen.

Key features

Membrane separation

Ube modules, 3–20 by flow.

High-pressure boost

V-type piston, 3/4 stages to 25/35 bar.

Dual drive

Electric or diesel for off-grid sites.

High flow

200–1,500 m³/h.

Model data

Models in this family

ModelFAD (m³/h)Pressure (bar)DriveGenset (kW)MembranesLubricationCoolingBooster typeNote
MZD-200-2502002575kw+45kw2003Oil-injectedAir cooledV-type piston, 3-stageelectric drive
MZD-200-3502003574kw+55kw2003Oil-injectedAir cooledV-type piston, 4-stageelectric drive
MZD-300-2503002590kw+55kw3004Oil-injectedAir cooledV-type piston, 3-stageelectric drive
MZD-300-3503003590kw+55kw3004Oil-injectedAir cooledV-type piston, 4-stageelectric drive
MZD-300-250-C30025TBD234V64Oil-injectedAir cooledV-type piston, 3-stagediesel drive
MZD-300-350-C30035TBD234V64Oil-injectedAir cooledV-type piston, 4-stagediesel drive
MZD-600-25060025185kw+132kw5008Oil-injectedAir cooledV-type piston, 3-stageelectric drive
MZD-600-35060035185kw+133kw5008Oil-injectedAir cooledV-type piston, 4-stageelectric drive
MZD-600-250-C60025TBD234V88Oil-injectedAir cooledV-type piston, 3-stagediesel drive
MZD-600-300-C60035TBD234V88Oil-injectedAir cooledV-type piston, 4-stagediesel drive
MZD-900-25090025250kw+185kw80012Oil-injectedAir cooledV-type piston, 3-stageelectric drive
MZD-900-35090035250kw+185kw80012Oil-injectedAir cooledV-type piston, 4-stageelectric drive
MZD-900-250-C90025KTA19+NTA85512Oil-injectedAir cooledV-type piston, 4-stagediesel drive
MZD-900-350-C90035KTA19+NTA85512Oil-injectedAir cooledV-type piston, 4-stagediesel drive
MZD-1200-250120025315kw+250kw88016Oil-injectedAir cooledV-type piston, 4-stagediesel drive
MZD-1500-150150015400kw+220kw88020Oil-injectedAir cooledV-type piston, 3-stageelectric drive
Full data for this product is confirmed in the order technical agreement — contact us for the sheet.
Related products

Related products

All products

← Back to products

Intelligent control

Sequencing, protection and logging in the panel

Control logic does not depend on an external platform or cloud service. Multi-unit sequencing, scheduled changeover, fault lockout and run logging all execute inside the control panel; communication ports are disabled and physically sealed at the factory and are enabled only when an interface is required.

Multi-unit sequencing

Units in the same air station are staged in bands by pressure: one machine acts as master and coordinates the group, the others load on demand. The unit with the lowest accumulated running hours starts first, so no single machine runs fully loaded while the rest stay idle.

Automatic load / unload

At the unload pressure the inlet valve closes and the blow-off valve opens; when pressure falls back to the load pressure the inlet reopens. If the unit runs unloaded beyond the set time it stops automatically, which avoids ineffective running hours.

Limit protection and reset lockout

Overload, phase loss, phase imbalance, voltage abnormality, high discharge temperature, high supply pressure, wrong phase sequence, low cooling water and sensor break are all monitored; any one of them trips the main circuit and locks the unit out. A manual reset is required before restart.

Consumable timing and dP criteria

Air filter, oil filter and separator are timed by running hours and monitored by differential pressure; lubricating oil and grease are timed separately. The panel indicates when an interval is due, and the maintenance interval is taken from the instrument records.

Run records and fault storage

Total running hours and total loaded hours are accumulated; the fault history is retained on power loss. On power-up the controller checks I/O, clock, A/D channels, communication ports and memory, and raises an alarm before entering run mode if a check fails.

Scheduled pressure and start/stop

Pressure setpoints can be switched by shift; outside production hours the unit goes to low-pressure standby or stops. Holiday periods can be set as a block, so no daily manual change of parameters is needed.

Unit 1Unit 2Unit 3
Control panelLoad/unload · Protection · Sequencing
DCS / host systemRS-485 · Modbus RTU
The master coordinates the group and the followers are rotated by accumulated running hours. Status and fault words are uploaded over one RS-485 link, with no additional gateway.

Communication: two RS-485 ports, Modbus RTU slave

One port is used for PID speed control of the panel-mounted VSD, the other for multi-unit sequencing or connection to a host system. Supply pressure, discharge temperature, running and loaded hours, load/unload status, fault words and start/stop commands are all standard registers; the register list is supplied with the unit.

  • 40001Supply pressure
  • 40002Discharge temp.
  • 40003Total run hours
  • 40009Fault / warning word

Cybersecurity: disabled at the factory by default

Marine models are configured to the relevant requirements of the China Classification Society Guidelines for Ship Cyber Security (GD027-2025):

  • No external data interface is brought out of the panel, there is no wireless module, and the unit is not connected to the ship's network.
  • No general-purpose operating system, no file system and no general network stack; the firmware runs directly on the microcontroller.
  • Unused ports are disabled in logic and physically sealed: insulating plugs, protective covers and tamper-evident seals, each individually marked.
  • Multi-level password authorisation; parameters cannot be changed without authentication. User-level parameters are locked before shipment.
  • Remote update and remote configuration are not supported; there is no USB or other external storage interface in the panel.

Send us the duty point — we reply with a sized proposal

Flow, pressure, cooling water, power supply, class society and delivery port: six items are enough.

Online SelectorRequest a Quote